Biltema

Reset

If the cells are not in deep discharge, the problem will be that the BMS goes into a fault mode, and must be reset. Look at the clip here:

https://www.youtube.com/watch?v=23SVz23RkbA

Short version:

  • Open
  • Cut the tape up over the BMS
  • Remove the sense connector
  • Remove B- (screwed connector)
  • Use a multimeter to measure B- to B+ until the reading goes down to below 20 mV
    • B- is called VG on the board (voltage ground)
    • P- is called DISC on the board (discharge)
    • P+ is called PACK+ on the board
    • The red RS multimeters go crazy with such low voltage, use other one
  • Same on P- to B+
  • Plug back B-, then the sense
  • Test charging
  • Put everything back together

image.png

Discharge test

image.png

Pinout of 7S BMS

image.png